Home >  Underlay > Counterflame
 
Underlay : Counterflame

 

Highly recommended for Maritime Vessels and Offshore Installations

Super-High Density Latex Foam Underlay with strictest Flame Retardant Properties.

Suitable for Heavy Foot and Wheel Traffic, Minimizes Carpet Rucking.

Suitable for both Stretch-Fit and Double-Stick Installations.

Passes IMP Resolution A653 (16) Flammability Test.

Carries European Directive 96/98 EC Marine Mark.

Lloyd's Register and Det Norske Veritas Approved.

Guaranteed for the Serviceable Lifetime of the Carpet when used in the Recommended Locations

TECHNICAL SPECIFICATIONS:
(Test Results To BS. 5808: 1991 - British Standard For Carpet Underlays)
SPECIFICATION BS REQUIREMENTS RESULT METHOD
WEIGHT   1600 g/mē   
THICKNESS   6.25 mm BS 4051
ROLL SIZE   1.37m x 11m  
MEAN ORIGINAL THICKNESS FROM NOMINAL THICKNESS Maximum 12% 3.0% BS 4051
DIFFERENCE BETWEEN MAX./ MIN. ORIGINAL THICKNESSES Maximum 3mm 0.6 mm BS 4051
BREAKING STRENGTH
Length
Width
Minimum 40N  
356 N
141 N
BS 2576
EXTENSION UNDER FORCE
Length
Width
Maximum 10% @ 40N  
1.6 %
0.5%
BS 2576
WORK OF COMPRESSION Min. 50 J/mē after dynamic loading for 1000 impacts 93 J/mē BS 4098
& BS 4052
COMPRESSION AFTER DYNAMIC LOADING Minimum 2mm, maximum 7mm after 1000 impacts 3.2mm BS 4098
& BS 4052
RETENTION OF WORK OF COMPRESSION Min. 40% of original after dynamic loading for 1000 impacts 89% BS 4098
& BS 4052
LOSS IN THICKNESS AFTER DYNAMIC LOADING Max. 15% after 1000 impacts 11.2% BS 4052
LOSS IN THICKNESS AFTER STATIC LOADING Max. 15% after 24 hrs recovery 5.7% BS 4939
RESISTANCE TO CRACKING Not greater than 50mm Pass BS 5808
ODOUR No objectionable odour Pass BS 5808

FLAMMABILITY     
I.M.O. SURFACE FLAMMABILITY TEST OF BULKHEAD, CEILING AND DECK FINISH MATERIALS AS AMENDED BY RESOLUTION MSC 61 (67) Pass - Materials meets all the criteria given in the IMO document & can therefore be considered to have low flame spread in compliance with the International Convention for the Safety of Life at Sea, 1974. Resolution A653 (16)
HOT METAL NUT TEST Pass - Low radius of effects of ignition BS 4790
CAA Vertical Flame Test Pass

CAA Spec 8 & FAR/JAR
25853a App. F, Pt. 1 (A) 1 (ii)

French Radiant Panel Class M3 NFP 92-506
IMO Surface Flammability Test Pass Resolution A653(16), amended by MSC61(67)

SMOKE AND TOXICITY     
I.M.O. SMOKE & TOXICITY TEST Pass   Resolution
MSC 61 (67) 1996
Annex 1, Part 2
ORIGIN United Kingdom (Duralay)
END USE OF CLASSIFICATION HC/U (Heavy Contract Use) BS 5808

< Back to Underlay < Previous collection > < Next collection >
 
 
 